Cisco Cisco OptoStar II 1550nm EDFA Installationsanleitung
Operating using NMS Software
This section introduces the procedures to use the OptoStar II network
management system (OptoStar II NMS) to manage the OptoStar II 1550 nm
optical amplifier module.
management system (OptoStar II NMS) to manage the OptoStar II 1550 nm
optical amplifier module.
Before You Begin
•
One PC
•
A network cable
•
OptoStar II NMS software installation package
System Requirements
•
Supported operation system: Windows 7, Windows Server 2008, Windows
Vista, and Windows Server 2003
Vista, and Windows Server 2003
•
Processor: 400 MHz Pentium or equivalent processor (minimum requirement);
1 GHz Pentium or equivalent processor (recommended)
1 GHz Pentium or equivalent processor (recommended)
•
Memory: 512 MB (minimum requirement); 1 GB (recommended)
•
Hard drive: 500 MB free space required
•
Monitor: 800 x 600, 256-color (minimum requirement); 1024 x 768 high color,
32-bit (recommended)
32-bit (recommended)
Start
1. Make sure that the fibers of the OptoStar II 1550 nm optical amplifier module
are connected.
2. Turn the front panel switch of the OptoStar II power supply module to ON
position. The power supply module and the 1550 nm optical amplifier module
will initialize for about 5 seconds, and the ICIM will load for about 25
seconds.
Note: The system will achieve optimal working condition after one hour’s
warm-up.
will initialize for about 5 seconds, and the ICIM will load for about 25
seconds.
Note: The system will achieve optimal working condition after one hour’s
warm-up.
3. When the device initialization is complete, connect to the Ethernet with the
RJ-45 connector on the rear panel of the ICIM. Connect the PC to the Ethernet.
The illustration below shows the connection method.
The illustration below shows the connection method.