Operating using ICIM LCD, Continued
Sub-menu 2 -- RF Input Alarm Threshold
The illustration below shows sub-menu 2 of the OptoStar II RF switch module –
RF Input Alarm Threshold.
RF Input Alarm Threshold.
The default value of RF input alarm is 3 dB. In auto switching mode, if the
calibrated signal value is out of this range, the module will alarm and perform
auto switching according to different conditions (refer to Page 3-7).
1. Press SET button to start the configuration;
2. Press ▲▼ buttons to change the value, and press SET button to confirm
calibrated signal value is out of this range, the module will alarm and perform
auto switching according to different conditions (refer to Page 3-7).
1. Press SET button to start the configuration;
2. Press ▲▼ buttons to change the value, and press SET button to confirm
(alarm range: 3~10 dB, 1dB step);
3. Press ► button to move the cursor to “Set”;
4. Press SET button to save the configuration.
4. Press SET button to save the configuration.