Cisco Cisco OptoStar II 1550nm Transmitter Installationsanleitung
Operating using Console Software, Continued
Setup Parameters
The table below lists the setup parameters of the OptoStar II reverse receiver
module.
module.
Setup Parameters Description
Factory Default
Optical Alarm
Threshold
Shows/sets optical alarm high
limit and low limit
Low limit: - 17.0 dB
High limit: + 3.0 dB
High limit: + 3.0 dB
Module Alarm
Enable
Shows / sets module alarm status
Alarms of all the four
modules are enabled
Test Point
Shows / sets module test point or
no test point
No Test Point
Alarm ON/OFF
Shows / sets module alarm status:
ON/OFF
Alarm ON/OFF corresponds with
Alarm ON/OFF corresponds with
Module Alarm Enable: for
example, if only Module 1 and
Module 2 need to be monitored,
then select Module 1 and Module 2
in Module Alarm Enable, and
Alarm ON/OFF in ON position.
Alarm status: ON
Gain Control
Mode Selection
for Four Modules
Shows / sets AGC or MGC gain
control mode
AGC mode for all
four modules (0 dB in
MGC mode)
3-22
Operation
OL-29663-03