Cisco Cisco OptoStar II Reverse Receivers Installationsanleitung
Operating using ICIM LCD, Continued
Sub-menu 7 -- Module Alarm Enable
The illustration below shows sub-menu 7 of the OptoStar II reverse receiver
module - Module Alarm Enable.
module - Module Alarm Enable.
By default, the module alarms of four reverse receiver modules are enabled and
the cursor is on Module 1.
the cursor is on Module 1.
•
To enable/disable the alarm of another module:
1. Press ▲▼ buttons to select another module;
2. Press SET button to select alarm enabled/disabled; symbol stands for
2. Press SET button to select alarm enabled/disabled; symbol stands for
enabled and symbol stands for disabled;
3. Press ► button to move the cursor to “Set”;
4. Press SET button to save the configuration.
4. Press SET button to save the configuration.
Continued on next page
3-14
Operation
OL-29663-03