Operating using ICIM LCD, Continued
Alarm Code List
The table below lists the alarm information of the OptoStar II reverse receiver
module.
module.
Code
Item
Condition
LED
001
Module 1 Low Optical
Input Power
Input Power
Optical input power
lower than -17 dBm
lower than -17 dBm
Alarm LED is red
002
Module 1 High Optical
Input Power
Input Power
Optical input power
higher than 3 dBm
higher than 3 dBm
Alarm LED is red
003
Module 2 Low Optical
Input Power
Input Power
Optical input power
lower than -17 dBm
lower than -17 dBm
Alarm LED is red
004
Module 2 High Optical
Input Power
Input Power
Optical input power
higher than 3 dBm
higher than 3 dBm
Alarm LED is red
005
Module 3 Low Optical
Input Power
Input Power
Optical input power
lower than -17 dBm
lower than -17 dBm
Alarm LED is red
006
Module 3 High Optical
Input Power
Input Power
Optical input power
higher than 3 dBm
higher than 3 dBm
Alarm LED is red
007
Module 4 Low Optical
Input Power
Input Power
Optical input power
lower than -17 dBm
lower than -17 dBm
Alarm LED is red
008
Module 4 High Optical
Input Power
Input Power
Optical input power
higher than 3 dBm
higher than 3 dBm
Alarm LED is red
009
High Module
Temperature
Temperature
Module temperature
higher than 85°C
higher than 85°C
Alarm LED is red
3-16