Cisco Proteus Node Return Digital Transmitter with Ethernet Installationsanleitung

Seite von 53
78-4028521-01 Rev B 
Installation 
2-5 
Laser Link III Mainframe Electrical Connections 
Overview 
The Laser Link III Mainframe requires the following electrical connections: 
• 
Power supply 
• 
Power distribution board 
Power Supply Connections 
Connect the power supplies as described below. 
 
IF the primary input 
is… 
THEN… 
an AC power source 
connect the power cord to the mainframe and power 
source. 
a -48 V DC power 
source 
apply -48 V DC potential on the rear of the power supply, 
using the supplied connectors (and noting polarity).   See 
Rear Panel Drawing
 
Rear Panel Drawing 
The following illustration shows the rear panel. 
 
 
 
Important:  Connect the -48 V potential to the negative terminal.  Connect the 
ground potential (DC return) to the positive terminal.  Wire gauge specifications for 
the -48 V DC/13 A input are as follows: 
10’ cable:  17 AWG minimum 
5’ cable:  20 AWG minimum