 Engineering Rules   
▀  Interface and Port Engineering Rules 
 
 
▄  HNB-GW Administration Guide, StarOS Release 16 
138 
   
Interface and Port Engineering Rules 
The rules discussed in this section pertain to both the Ethernet 10/100 and Ethernet 1000 Line Cards and the four-port 
Quad Gig-E Line Card and the type of interfaces they facilitate. 
IuCS Interface Rules 
When supporting CS networks, the system can be configured to provide IuCS interface support and connects to the 
MSC in a CS network in same the PLMN. 
The following engineering rules apply to the IuCS interface between the HNB-GW and MSC: 
 
An IuCS interface is created once the IP address of a logical interface is bound to an ASP-IP defined in the SS7-
RD-instance which is defined in SCCP Network instance which is defined in CS Network configuration based 
on destination point-code. 
 
The logical interface(s) that will be used to facilitate the IuCS interface(s) must be configured within the egress 
context. 
 
CS Network services must be configured within the local context. 
 
Multiple MSCs (maximum 25) can be configured through IuCS interfaces within the HNB-GW service instance. 
IuPS Interface Rules 
When supporting PS networks, the system can be configured to provide IuPS interface support and connects to the 
SGSN in a PS network in the same PLMN. 
The following engineering rules apply to the IuPS interface between the HNB-GW and SGSN: 
 
An IuPS interface is created once the IP address of a logical interface is bound to a PS Network service. 
 
The logical interface(s) that will be used to facilitate the IuPS interface(s) must be configured within the egress 
context. 
 
PS Network services must be configured within the local context at the system level. 
 
Multiple SGSNs (maximum 25) can be configured through IuPS interfaces within the HNB-GW service 