Cisco Cisco Packet Data Gateway (PDG) Fehlerbehebungsanleitung

Seite von 296
  Troubleshooting the  System 
Detecting Faulty Hardware Using Component LEDs  ▀   
Cisco ASR 5000 Series System Administration Guide  ▄  
 
  OL-22970-01 
RCC Standby LED States 
The Standby LED on the RCC indicates that software is loaded on the card and is ready to provide a path for data or 
signalling traffic from a line card to a redundant PSC. This LED should be on for normal operation for both RCCs 
installed. 
 
The possible states for this LED are described in the following table. If the LED is not green, use the troubleshooting 
information in the table to diagnose the problem. 
Table 40. 
RCC Standby LED States 
Color
 
Description
 
Troubleshooting
 
Green
 
Card is in standby 
mode
 
This is the normal operating mode. 
None
 
Card is not receiving 
power ORCard in 
Active Mode
 
 
Verify that the RUN/FAIL LED is green. If so, the card is receiving power and POST 
test results are positive. If it is off, refer to the RCC RUN/FAIL LED States section of 
this chapter for troubleshooting information. 
 
Check the state of the Active LED. If it is green, the card is in active mode and the 
RCC is actively routing traffic from a line card installed behind a PSC that has failed. 
 
Refer to either the Checking the LEDs on the PAC(s) or Checking the LEDs on the 
PSC(s)
 section of this chapter to determine which PSC has failed. Information on 
determining the cause of the failure can be found in the Monitoring the System chapter 
of this reference. 
 
 
Testing System Alarm Outputs 
The system provides the following two physical alarm mechanisms: 
 
 
 
System Audible Alarm: Located on the SMC, the speaker is used to provide an audible indicator that a minor, 
major, or critical alarm has occurred. 
 
CO Alarms Interface: Located on the SPIO, this interface provides a 10-pin connector that enables three 
normally-closed dry-contact relays for the triggering of external audio and/or visual indicators. These 
indicators can be used to alert that either a minor, major, or critical alarm has occurred. 
The operation of these alarms can be tested by issuing the following command: 
Keyword/Variable
 
Description
 
 
Tests the CO Alarm Speaker on the SMC to verify operation.