Brother QL-700 Verweisanleitung

Seite von 37
 
 
2.Overview 
The printing procedure is described below. For details on each command, refer to “
By using the machine’s button (E/EL), QL-700 can be switched between operating in the printer class and 
the mass storage class. 
These materials assume that the machine is operating in the printer class.
 
 
①  Open USB/Serial/Network port 
Open the USB/Serial/Network port in the operating environment. The procedure for opening the 
USB/Serial/Network port is not described in this material. 
The serial port can only be used with the QL-580N/650TD/1050/1060N. 
The network port can only be used with the QL-580N/1060N. 
②  Check machine status 
The “Status information request” command is sent to the printer, the status information received from 
the printer is analyzed, and then the status of the printer is determined. For details on the “Status 
information request” command and on the definition of “status”, refer to “Status information request” in “
”. 
 
③  Send print data 
If the status analysis concludes that a tape cassette corresponding to the print data is loaded into the 
printer and that no error has occurred, the print data is sent. The structure of the print data is explained in 
”. 
Note: 
No command can be sent to the printer after the print data is transmitted and until the completion 
of printing is confirmed. 
Even the “Status information request” command cannot be sent during printing. 
 
④  Confirmation of printing completion 
When printing is completed, the status is sent from the printer. This status is analyzed and, if printing 
is completed, one page is printed. If the print job has multiple pages,  ② through ④ are repeated. 
 
⑤  Close USB/Serial/Network port 
After all printing is finished, close the USB/Serial/Network port. 
 
Note: 
In order to print at high speed when the USB port is used, the Brother QL starts printing when it 
starts to receive print data, instead of waiting for a print command. For the processing flow, for 
”. 
(If the printing data is compressed in Command “4D H + 02 H” for QL-580N/650TD/1050/1060N, the 
printer starts printing after a print command.) 
Brother QL-500/550/560/570/580N/650TD/700/1050/1060N Command Reference   