Brother RJ-4030Ai Verweisanleitung

Seite von 48
Raster Command Reference 
 
 
- 33 - 
5. MCR Command Specifications 
Reading multiple tracks 
Data in the above-mentioned format is combined for the specified number of tracks and sent. 
Example: Reading Track 1 and Track 2 
54h 
31h 
3Ah 
[data] 
0Dh 
0Ah 
54h 
32h 
3Ah 
[data] 
0Dh 
0Ah 
[data] 
CR 
LF 
[data] 
CR 
LF 
 
Condition 
Failed Reception Response (Timeout) 
Response 
Hex 
54h 
30h 
3Ah 
[“timeout”] 
0Dh 
0Ah 
ASCII 
[“timeout”] 
CR 
LF 
 
 
 
 
Character string 
“timeout” 
Delimiter 
 
Description 
Response indicating that it returned to the MCR off status due to a timeout 
[“timeout”]: The character string “timeout” is entered. 
Hex 
74h 
69h 
6Dh 
65h 
6Fh 
75h 
74h 
ASCII 
 
 
Condition 
Failed Reception Response (Read Error) 
Response 
Hex 
54h 
30h 
3Ah 
[“can not read”] 
0Dh 
0Ah 
ASCII 
[“can not read”] 
CR 
LF 
 
 
 
 
Character string “can 
not read” 
Delimiter 
 
Description 
Response indicating that an error occurred while reading 
[
“can not read”]: The character string “can not read” is entered. 
Hex 
53h 
41h 
4Eh 
20h 
4Eh 
4Fh 
54h 
20h 
52h 
45h 
41h 
44h 
ASCII 
 
 
 
 
 
 
Space 
 
 
 
Space