Brother RJ-4030Ai Verweisanleitung

Seite von 48
Raster Command Reference 
 
 
- 37 - 
6. Flow Charts 
6.4 Cooling flow for USB connection 
 
Computer (host) 
Printer 
If there are no 
problems with the 
printer status 
(media, etc.), the 
data is transmitted. 
If there is a 
problem, an error 
appears. 
The status of the printer 
(media, etc.) is checked 
and a response is sent. 
Data received. 
Beginning printing 
without waiting for a 
print command 
Printing 
Displaying sending 
The printer is initialized. 
Status 
(Notification: 
“Cooling (started)”) 
Returned
 “NAK” from 
cooling 
Repeating reading of 
maximum and 
transmission timeout 
times. If the 
transmission timeout is 
exceeded, reading, 
and displaying  the 
cooling status if a high-
temperature error is 
returned. 
Failed 
Status (Notification: “Cooling (finished)”) 
Resuming printing 
Continuing reading. 
0 packets are returned 
while cooling. 
0 packet 
When cooling is finished, 
Notification: 
“Cooling 
(finished)
” is returned. 
READ 
READ 
Any jobs with errors 
remaining in the printer 
are cleared. 
Status information request 
Status (response to status information request) 
Sending control codes 
Sending raster data
 
Initialize 
Status 
(Phase change: 
“Printing”) 
Sending raster data
 
Sending raster data
 
Sending raster data
 
0 packet 
0 packet 
0 packet 
Sending raster data
 
Sending raster data
 
Sending raster data
 
Cooling occurred