Brother RJ-3150 Verweisanleitung
ESC/P Command Reference
- 88 -
5. Control Command Details
ESC i J
2D barcode (Aztec)
ASCII:
ESC
i
J or j
data
Decimal:
27
105
74 or 106
data
Hexadecimal: 1B
69
4A or 6A
data
Format:
ESC
i
J or j
[Parameters]
[Barcode data]
\\\
(1)
(2)
(3)
Parameters
(1) [Parameters]
If a value other than those listed is entered for a parameter, that parameter is specified with its default
value.
1. Cell size
[1-byte decimal] 1
[1-byte decimal] 2
[1-byte decimal] 3
[1-byte decimal] 4
[1-byte decimal] 5
[1-byte decimal] 6
[1-byte decimal] 8
[1-byte decimal] 10
Specifies the dot size per cell side.
Prints 1 dot per cell side.
Prints 2 dots per cell side.
Prints 3 dots per cell side. (default value)
Prints 4 dots per cell side.
Prints 5 dots per cell side.
Prints 6 dots per cell side.
Prints 8 dots per cell side.
Prints 10 dots per cell side.
Prints 1 dot per cell side.
Prints 2 dots per cell side.
Prints 3 dots per cell side. (default value)
Prints 4 dots per cell side.
Prints 5 dots per cell side.
Prints 6 dots per cell side.
Prints 8 dots per cell side.
Prints 10 dots per cell side.
2. Symbol
type
type
[1-byte decimal] 0
[1-byte decimal] 1
[1-byte decimal] 2
[1-byte decimal] 1
[1-byte decimal] 2
Full range (default value)
Compact
Auto setting
Compact
Auto setting
3. Error
correction
capacity
correction
capacity
[1-byte decimal] 1
–99
[Percentage (default value is 23)
4. Symbol
size
size
[Full range]
[1-byte decimal] 0
[1-byte decimal] 4
[1-byte decimal] 0
[1-byte decimal] 4
–32
Auto setting (default value)
Manual settings
[Compact]
[1-byte decimal] 0
[1-byte decimal] 1
[1-byte decimal] 0
[1-byte decimal] 1
–4
Auto setting (default value)
Manual settings
Note: Symbol size is fixed as AUTO when Symbol type is specified as AUTO.
5. Structured
Append
setting
Append
setting
[1-byte decimal] 0
[1-byte decimal] 1
[1-byte decimal] 2
[1-byte decimal] 1
[1-byte decimal] 2
Not partitioned. (default value)
Partitioned
Partitioned Specify the number of blocks
Partitioned
Partitioned Specify the number of blocks
6. Number of
blocks
blocks
[1-byte decimal] 2
–26
Partitioned Only valid when the number of blocks is
specified (Default it 2)
specified (Default it 2)
7. Message
ID
ID
Character string(Terminal
value is 00h)
value is 00h)
Invalid when append setting 0.