Chapter 4
4-3
##0100, ##0280, ##0281, ##0750, ##0753, ##0754, ##0755, ##0758, ##0759, ##0760, ##0763 ##0764, ##0765, ##0768, ##0769,##0770, ##0773, ##0775, ##0778,
##0780, ##0783, ##0785, ##0788
4.2.4.3 Detailed Discussions of Bit 3
0010-9957
Use it to select an appropriate reception mode after transmission of the CFR signal.
If errors occur frequently at time of reception because of the condition of the line, select 'high speed' for reception mode and, at the same time, selects 'do not receive'
for 'ECM reception.'
Memo: 
Any of the following error codes may be indicated at time of reception because of line condition
##0107, ##0114, ##0201
Be sure to change bit 4 before changing this bit; if errors still occur, change this bit.
When 'high speed' is selected, only high-speed signals (images) will be received after transmission of the CFR signal.
4.2.4.4 Detailed Discussions of Bit 4
0010-9958
Use it to select the time length during which low-speed signals are ignored after transmission of the CFR signal.
If the condition of the line is not good and, therefore, the reception of image signals is difficult, select '1500 ms.'
4.2.4.5 Detailed Discussions of Bit 6
0010-9989
Selects whether or not to transmit CNG signal during manual transmission.
In manual transmitting to a fax with the FAX/TEL switching mode, if there are frequent errors due to failure to switch to fax mode, select "Transmitted" for the
CNG signal.
4.2.4.6 Detailed Discussions of Bit 7
0010-9990
Selects whether or not to transmit CED signals during manual reception. If the other fax does not transmit even when you start manual reception, select "Transmit-
ted" for the CED signal.
4.2.5 SSSW-SW05: Setting of Standard Functions (DIS signal)
4.2.5.1 List of Functions
0010-9991
T-4-4
4.2.5.2 Detailed Discussions of Bit 1
0010-9993
Use it to enable/disable millimeter/inch conversion in sub scanning direction for images read in text mode.
Scanning direction in conversion follows the Bit 2 setting of SW14.
4.2.5.3 Detailed Discussions of Bit 2
0010-9995
Use it to enable/disable millimeter/inch conversion in sub scanning direction for images read in text/photo mode while bit 1 is set to '1'.
Scanning direction in conversion follows the Bit 2 setting of SW14.
4.2.6 SSSW-SW12: Setting of Page Timer
4.2.6.1 List of Functions
0010-9996
T-4-5
The machine will stop the ongoing communication if the transmission/reception of a single original page takes 32 min or more. To use the timer for a purpose other
than this function, refer to the tables that follow, and select an appropriate time length.
When 'do not enable' is selected using bit 7, the time-out length for a single page for all modes will depend on the setting of bit 0 and bit 1.
T-4-6
Bit
Function
1
0
0
not used
-
-
1
Conversion from mm to inch (text mode)
convert
do not convert
2
Conversion from mm to inch (text/photo mode)
convert
do not convert
3
not used
-
-
4
not used
-
-
5
not used
-
-
6
not used
-
-
7
not used
-
-
Bit
Function
1
0
0
Time-out period for one page upon transmission
1
0
1
Time-out period for one page upon transmission
1
0
2
not used
-
-
3
not used
-
-
4
Time-out period for one page upon reception
1
0
5
Time-out period for one page upon reception
1
0
6
not used
-
-
7
Respective page timer settings for transmission and for 
reception
enable
do not enable
Time-Out Length for 
Transmission/Reception
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
8  min
0
*
*
*
*
*
0
0
16  min
0
*
*
*
*
*
0
1
32  min
0
*
*
*
*
*
1
0