Acer altos s300

Seite von 78
 3 Cabling and configuration
32
Delayed Start
If you select this option, the disk drives will spin up sequentially i.e. not 
all together.  To enable this feature, install a jumper at location JP11 
on the ESM and CSM (whichever is installed).  If two CSMs are installed, 
the jumper should be installed on both CSMs.
Powering on an AC enclosure
1.
Ensure all cables have been attached as described in the preceding 
sections.
2.
Attach the AC power cords to the power supplies and turn the 
power supply switches to the On (-) position (see figure below).
3.
Power on the host system and the Altos S300 series enclosure will 
power on also.
Note:  Powering off all the attached host systems will power off 
the Altos S300 series enclosure also.  Refer to “Power up” on page 
31 (
jumper JP13).
Warning!  This equipment must be connected to an earthed 
mains socket outlet.  Ensure the power cabling provides 
earthing continuity to the equipment.
1
2
1
2
0
I
0
I
Insert Power cords into 
power connectors
Mute