a1-security omnicron 9000 Benutzerhandbuch
Omnicron
9000 series
Installation and programming Instructions
Default settings on power up
User code 1234
Part set code 0000
Engineer code 9999
Cleaner code 7777
Exit time 30sec
Entry time 30sec
Bell Time 20min
Speaker time 20min
User reset YES
Relay activation in part set YES
Mains LED OFF (when armed)
PA (sounder & relay) NOT SILENT
Auto re-arm YES
Bell delay OFF (0sec)
Speaker delay OFF (0sec)
Zone 1 E/E in part set YES
Intermediate zones NONE
Part set zones NONE
Self-monitoring zones NONE
Double knock NO
To Enter ENGINEER MODE
Press
Reset key and enter current user code (1234)
Then press
program.
Green
CLEAR led will flash.
Enter 99 then current eng. code (9999)
Red
ENGINEER LED will flash continuously, indicating the panel is in engineer mode.
YOUR NOW IN ENGINEER MODE.
Downloaded from: http://www.guardianalarms.net