a1-security aj600 Benutzerhandbuch

Seite von 1
AJ600 Quick Reference 
 
User code default -1234 
 
 
To reset panel defaults disconnect BOTH the mains supply and battery. 
Items in BOLD are keys on the alarm panel which need to be entered in the order stated. 
 
 
User codes 
 
RESET - PROG FUNCTION - USER CODE (1234) 
The DAY LED will flash. 
 
Followed by: - 
 
to set NEW USER CODE. 4 zones will illuminate. Key in new 4-digit code. Each digit extinguishes a 
zone LED. 
 
On the final digit the panel will sound a two-tone acceptance bleep. PROG FUNTION to store. 
 
to set CHIME on or off for each zone. Handy for front and back door zones but can be a nuisance on 
frequent triggered zones. PROG FUNTION to store. 
 
to TEST EXTERNAL SIREN/ STROBE (the day LED will remain on) then :- 
to test / silence SIREN or to test STROBE. 
 
RESET to enter normal mode
.