 Troubleshooting
Symptom Charts/System - 3
 
System
 
Does not power on; 
screen is black, fan is 
not running and LED 
is not lit
1 Check cables.
2 Plug monitor directly into wall socket, and verify that 
monitor has power.
3 Replace power cord.
4 Replace power supply.
5 Replace logic board.
Clicking, Chirping or 
thumping
1 Replace power supply.
2 Replace logic board. Retain customer’s SIMMs.