APart MA246R Benutzerhandbuch

Seite von 6
WWW.APART-AUDIO.COM
INFO@APART-AUDIO.COM
INPUTS
MIC/LINE 1 
balanced input on euroblock
Sensitivity mic/line: 
variable 3mV to 2V
Impedance: 
600 ohm
S/N mic/line: 
>65dB/>80dB
Phantom power: 
NA
Frequency response: 
80Hz - 15 kHz (+1/-3dB) speech eq
Muting activated by contact: 
mutes inputs with lower priority by more than 
40dB
MIC/LINE 2-4 balanced inputs on euroblock
Sensitivity mic/line: 
variable 1,5mV to 200mV
Impedance: 
600 ohm
S/N mic/line: 
>65dB/>80dB
Phantom power: 
18 VDC
Frequency response: 
80Hz - 15kHz (+1/-3dB) speech eq
Muting activated by contact: 
> 40dB; priority according to priority table
EMERGENCY INPUT transformer coupled balanced input on euroblock
Sensitivity: 
1V
Impedance: 
600 ohm
S/N: 
>80dB
Frequency response: 
100Hz - 20 kHz (+1/-3dB)
Muting: 
Activated by contact or vox (selectable inside the unit) 
Emergency has highest priority and mutes all other inputs by more than 40 dB. The signal is also present on 
the preamp out,
AUX 1 - 2 unbalanced stereo input on RCA
Sensitivity: 
500mV
Impedance: 
22 kilo ohm
S/N: 
>80dB
Frequency response: 
40 - 25 kHz +1/-3dB, Signal is internally mixed 
to mono
AUX 3 - 4 unbalanced mono input on RCA
Sensitivity: 
500mV
Impedance: 
22 kilo ohm
S/N :
>80dB
Frequency response: 
40 - 25 kHz +1/-3dB