advantor advantage plus-4250 base module Benutzerhandbuch

Seite von 14
2
Zone - An area of the facility that contains alarm loops that arm and
disarm as a group with associated auxiliary outputs and audio
verification or audio detection AudioSensors.
SCOPE
These instructions provide the information and references needed to
install, set up, and option UL Listed Advantage plus systems
using the UL Listed Base Module as the system control unit. The
Advantage plus Service Manual” (P/N 09820460) covers system
maintenance and service.
THE ADVANTAG
E plus 
UL SYSTEMS
The Advantage plus system has following UL Listings and
agency approvals:
FCC Part 15, Class B
UL 294, “Access Control System Units”
UL 365, “Police Station Connected Burglary Alarm Units and
Systems”
UL 609, “Local Burglar Alarm Systems and Units”
UL 864, “Control Units for Fire Protective Signaling Service”
UL 985, “Household Fire Warning System Units”
UL 1023, “Household Burglar-Alarm Systems”
UL 1076, “Proprietary Burglar Alarm Units and Systems”
UL 1610, “Central Station Burglar Alarm Units”
CSFM (California State Fire Marshal)
The Advantage plus Base Module is the primary control unit for
Advantage plus systems. The Base Module directs and controls
all other optional modules and devices and provides communica-
tion with the SONICS central station monitoring console.
The Base Module, without any optional add-on modules,  has the
following features and capabilities:
• sixteen programmable alarm loops
• up to eight separate zones
• four auxiliary outputs
• four audio inputs for verification audio
• dedicated or dial telephone line operation
• one Wiegand card reader input
• an RS-485 communication port
The Base Module’s RS-485 communication port can interface and
control the following optional add-on modules and devices to expand
the system’s features and capabilities:
• any combination of 16 LCD plus and LED plus keypads
• eight alarm loop Expansion Modules
• a combined total of eight SmartAudio Modules and/or
ListenIn audio verification modules
• seven Access Modules
NOTE:
See the following documents for Advantage plus
optional module installation instructions:
• Access Module Installation, P/N 09820451
• Smart Audio Module Installation, P/N 09820452
• Expansion Module Installation, P/N 09820453
• TelPlus Module Installation, P/N 09820454
• Wireless Module Installation, P/N 09820456
• ListenIn Module Installation, P/N 09820455
• Cellular Module Installation, P/N 09820457
• APS12V1A-S Power Supply, P/N 09820458
• LED plus Keypad Installation, P/N 09830030
• LCD plus Keypad Installation, P/N 09830046
• Fire Control Panel Interface Installation, P/N 09820459
Each of the listed add on devices and modules can be located up to
2,000* feet from the Base Module giving the Advantage plus the
following maximums:
• 214 alarm loops split into eight separate zones
• any combination of up to 128 audio detection/audio verifica-
tion audio sensors
• access control of up to 28 separate doors
• up to 82 programmable auxiliary outputs
*NOTE: At least one LCD plus or LCD plus keypad must be
powered directly from the Base Module.
ADVANTAG
E plus PROPRIETARY AND
CENTRAL STATION BURGLARY SYSTEMS
The major differences between the Advantage plus UL Propri-
etary Burglary systems and standard Advantage plus installa-
tions are:
Must be installed per UL 681, “Installation and Classification of
Mercantile and Bank Burglar Alarm Systems”
 and UL 611,
“Central Station Burglar Alarm Systems.”
Requires the UL Listed chassis and the tamper switch assem-
bly, available from Advantor.
UL Certificated Burglary Systems may use only LCD or LCD
plus keypads as the system Arming/Disarming device.
Proprietary burglar alarm systems provide Grade AA alarm
loops.
UL Burglary Systems require a minimum of 4 hours of standby
(battery) power.
OPTIONS SELECTION AND PROGRAMMING
NOTE:
See the “SONICS Database Management Manual”
(P/N 09840015) for complete option descriptions.
The alarm monitoring console displays different screens for each
Advantage plus series.  For example, selecting the Panel Type
and UL Fire automatically locks in many UL required options and
limits other option selections in specific fields.
Advantage
 plus 
Central Station Fire Options
The following lists the required central station fire options.
Equipment Options
Select “ADV” panel type and “plus” for the series
Select “LCD Keypad.”
Select “TelPlus.”
An annunciator (if used) must be supervised. (See the Household
File loop and auxiliary output options.)
Phone Options
Program the Wait for Dial Tone option for 7 seconds or less.
Option the Central Station Response Time (CSR) option for 45
seconds or less.
Program the Enable Line Monitor 2 for Yes.
Loop Options
To meet the UL requirement that fire alarms have the highest
priority, Fire-related Alarm Codes should be the following:
    -
FIRE  ALARM
   - FIRE LOOP #
All UL Fire-related loops restricted to 24-Hour security.
All UL Fire-related loops restricted to Send Restoral Code.
All UL Fire-related loops default to Alarm on Short.
All UL Fire-related loops restricted to Send Trouble When Armed.
All UL Fire-related loops restricted to Drop Line alarm reporting.
All UL Fire-related loops restricted to Fire Loop.