CAUTION
  Cleaning with solvents  may degrade  some  respirator  components  and  reduce  respirator  effectiveness.
See Maintenance and Cleaning section.
  Inspect all respirator  components  before each use to ensure proper operating  conditions.
  The used  cartridge must  be disposed of in accordance with all applicable waste regulations.
  Avoid overstretching  the  holes  in  the  universal  second  skin.   To  prevent tearing  the  exhalation  valve
cover opening of  the  universal  second  skin,  be  careful  pulling  it over the flanges  of  the  exhalation  valve
housing.
  DS2  is  a  common  agent  used  in  the  decontamination  of  equipment  exposed  to  military  chemical
warfare  agents.  DS2  may damage  the  front and side voicemitters of  the  mask assembly. When exposed
to DS2,  rinse  voicemitters with clean  water.
USE  INSTRUCTIONS  AND  LIMITATIONS
Important
Before use the wearer must read and understand these  User  Instructions.  Keep these instructions for
reference.
FR-C2A1 is NIOSH approved for chlorine, hydrogen chloride, sulfur dioxide, chloroacetophenone (CN),
o-chlorobenzylidene malononitrile (CS) and P100.  See 3M™ FR-C2A1 Cartridge  User  Instructions,
Specification section.
FR-64 is NIOSH approved for certain organic vapors, sulfur dioxide, chlorine, hydrogen chloride,
chlorine dioxide, hydrogen fluoride, ammonia, methylamine, formaldehyde, hydrogen sulfide (escape
only), phosphine , chloroacetophenone (CN), o-chlorobenzylidene malononitrile (CS) and as a P100
particulate filter. See 3M™ FR-64 Cartridge  User  Instructions, Specification section.
Note, the FR-C2A1 Cartridge:
– 
Meets canister requirements for protection against CS, CN.
– 
Meets cartridge requirements for chlorine, hydrogen chloride and sulfur dioxide.
– 
Filter meets 42 CFR 84 P100 requirements.
– 
Meets the gas testing criteria of U.S. Military Specification MIL-C-51560(EA) and EA-C-1704.
– 
Is  not  NIOS H evaluated for any other gases or vapors.
Note, the FR-64 Cartridge:
-
Meets canister requirements for protection against H
2
S(escape only), Phosphine, CS, and CN.
-
Meets cartridge requirements for certain organic vapors, sulfur dioxide, chlorine, hydrogen chloride,
chlorine dioxide, hydrogen fluoride, ammonia, methylamine and formaldehyde.
-
Filter meets 42 CFR 84 P100 requirements.
Meets certain gas testing criteria of U.S. Military Specification MIL-C-51560 (EA), EA-DTL=1704A,
NATO triptych AC/225 (Panel VII D/103 and QSTAG 1009.
Use For
3M recommends the use of this product to help reduce the respiratory exposure of wearers to certain
chemical and biological warfare agents when used in accordance with all use and limitation instructions
and applicable safety and health regulations.