Avision av8000s Benutzerhandbuch

Seite von 57
 
10-3 
 
10.3  CLEANING THE ADF 
From time to time the pad assembly and feeding rollers 
may become contaminated with ink, toner 
particles or paper dust.  In this case the 
scanner may not feed documents smoothly or several 
documents may feed at once.  If this occurs please 
follow the cleaning procedures to return your scanner to 
its original state.   
i).  Moisten a cotton swab with isoprophyl alcohol 
(95%).  (Cleaner kits are available from 
PictureVision.) 
ii). 
Carefully open the ADF to the left . Wipe the 
feeding rollers by moving the swab from side to 
side.  Rotate the rollers forward with your finger 
and repeat the above cleaning procedures until 
the rollers are clean.  Be careful not to snag or 
damage the pick springs. 
iii). 
Wipe the pad in the direction from top to bottom.  
Be careful not to hook the pick springs. 
iv). 
Close the ADF unit.  Your scanner is now ready 
for use. 
 
Opening the ADF unit and Document Cover   
 
 
ADF 
feed 
module 
ADF 
Feeding 
Rolle