australian-monitor sy2200 Benutzerhandbuch

Seite von 12
C O N T R O L S ,   C O N N E C T O R S   &   I N D I C AT O R S
PA G E  5
S Y N E R G Y   2   –   O P E R AT I O N   M A N U A L
7
1
2
3
4
5
 Power 
Switch
Press the switch to  up for power on and down for 
power off. At start-up (turn-on), the input to the 
amplifi er is muted for approximately two seconds.
 Thermal 
Indicator
In the advent of a thermal overload, this LED will 
turn red, indicating that the internal operating 
temperature of one or both amplifi er channels has 
exceeded a safe level of operation and the 
channels will be automatically muted. The fans 
will continue to run and once the effected 
channel/s have cooled, they will un-mute and 
return to normal operation.
 On 
Indicator
This LED will illuminate blue and indicates that the 
amplifi er is on and receiving mains power.
 Fault 
Indicator
This red LED indicates a signifi cant problem with 
the amplifi er and the amplifi er should be returned 
to an authorised technician for servicing.
 Attenuator
Level control for your amplifi er is provided by a 
potentiometer on the front panel and indicates 
gain. There are 2 controls on all Synergy-2 models. 
Each control is labelled for the channel which it 
operates.
 
 
 Status 
Indicator
This is a dual colour LED which displays the status 
of the output stage and displays three levels of 
operation.
These levels are: 
Below 1 watt  
(unlit)
1 watt and above  
(green)
Clipping  
(red)
The LED will turn green once the output voltage 
exceeds 2.828 volts (1 watt re 8 ohms).
The LED will change to red once the output 
reaches the threshold of clipping of the amplifi er’s 
output stage. The threshold of clipping is referred 
to the amplifi er supply rails and alters with 
changes in the mains supply, changes in the load 
and duty cycle fl uctuations.
The attack and decay time (ballistics), of the status 
circuit are those of a Peak Programme Meter 
(P.P.M.)
If using this indicator to line up sensitivities, apply 
a steady state tone (e.g. slate on a mixing con-
sole). The 1 watt level is the mid-point between 
the indicator illuminating and extinguishing green.
 
NOTE: The amplifi er is not damaged by 
 
running into clipping, but speakers may be. 
 
To maximise the life of your speakers, try 
 
to keep clipping infrequent. 
 Overload 
Indicator 
This amber LED will illuminate when an overload 
condition exists. 
Overload conditions can occur under extreme 
operating conditions such as:
 
- complex or very low loads
 
- over driving the amplifi er
It should be noted that the minimum load for the 
amplifi er is 2 ohms per channel (4 ohm bridged).
If an overload occurs, the amplifi er will shut down 
and mute the channel output. If the overload is 
only transitory, then the amplifi er will resume 
normal operation after approximately 3 secs. If the 
fault is continuous, then the amplifi er will remain 
muted.
Front Panel
5
6
7
The Synergy-2 Series differ only slightly across all models and all share the same features on their front panels. 
Figure 1 shows the panel layout of a SY2200 Synergy-2 amplifi er. It is similar for the SY2400, SY2700 & SY2900. 
The functions of the controls and indicators are as follows:
1
4
2
3
 
NOTE: You should always ensure that the fan grille is kept clean and free from the build up of dust and lint. 
 
This will ensure longer operation of your amplifi er and reduce the possibility of it prematurely going into thermal 
 
shutdown mode. See the section “Installation - Cooling “ on page 14 for recommended cooling procedures.
6