australian-monitor sy 400 Benutzerhandbuch

Seite von 24
Australian Monitor
Features of the SY Series
]
]
]
]
]
Forced air cooled
Equipped with XLR male/female
inputs
Dual output connectors, binding
posts and 4 pole speaker
connectors
GND lift facility
Clip limiter circuit provided standard
]
]
Toroidal mains transformer
CE Approved (EMC & LVD)
Specifications 21
Model:
@ 4 ohms
0.1% THD
Single channel driven
710
Both channels driven
600W
(2 ohm loads not recommended)
Bridge mode
8 ohm load
1200W
(4 ohm bridging not recommended)
49.0
@ 1kHz
<0.018 ohms
(@ 1kH re 8 ohms)
> 450:1
>41 V/µs
@ 1KHz
Rated Power into 4 ohms (-3dB)
SY1200
Output Power
Voltage Gain
Output Impedance
Damping factor
Slew rate
Per Channel
W
15 Hz- 75 kHz
H,W,D = (87 x 482x450) mm
Shipping Weight = 17 Kg
Frequency response
Dimensions
Input Power
1650 VA
Model:
@ 4 ohms 0.1% THD
Single channel driven
920
Both channels driven
800W
(2 ohm loads not recommended)
Bridge mode
8 ohm load
1600W
(4 ohm bridging not recommended)
56.5
@ 1kHz
<0.019 ohms
(@ 1kH re 8
)
> 430:1
>41 V/µs
@ 1KHz
Rated Power into 4 ohms (-3dB)
SY1600
Output Power
Voltage Gain
Output Impedance
Damping factor
Slew rate
Per Channel
W
ohms
15 Hz- 62 kHz
H,W,D = (87 x 482x450) mm
Shipping Weight = 20 Kg
2100 VA
Frequency response
Dimensions
Input Power