act actprox product range Benutzerhandbuch
ACTproX1040/1050 Pin and Proximity
Reader (Entry)
ACTproX1030 Proximity
Reader (Exit)
Controller
SENSE
C
ard
/P
ro
x R
ea
de
r
2
3
1
5
6
4
8
9
7
0
White
Green
Blue
Red
Black
Brown
Yellow
Orange
SENSE
Clock / Data1
Data / Data 0
+5v
0v
Red Led
Grn Led
(Buzzer Ctrl)
Wiring for ACTProX Reader
The +5V reader supply on ACT controllers is normally rated
at 1A for the ACT 2000 and ACT 3000 Controllers and rated at
100mA for the ACT1000.
Typically this is sufficient to power 2 ACT readers; however
if you are using two readers with the ACT 1000 controller we
do recommend that you power the ACT Readers from 12v.
Note however that readers from other manufacturers may need
to be powered separately if their current requirements exceed
this or if they require 12v.
Readers must be placed a minimum of 1m from each other in
order to maximise reading range.
The standard wiring colours for
ACTProX Proximity and Pin readers
is shown above. Readers
should be a maximum of 30m
from the controller when powered
from +5V and a maximum of 100m
when powered from +12V.
OM
RO
N
5A
2
50
VA
C
5A
3
0V
DC
OM
RO
N
1A
12
5V
AC
1A
30
VD
C
5-12Vdc
0V
0 1 2 3 4 5 6 7 8 9
BATCH:
PRODUCT :
SERIAL NUMBER
:
02XX-1
ACTPro2 REV1.3
00XXXX
Data / D0
Clock / D1
Sense
Red LED
Grn LED
Buzz Ctrl
Internal buzzer is
activated by applying
0V to Buzz Ctrl
Rear view of ACTProX 1040/1050/1060
connected to the ACT3000/2000/1000/DS100
Unit C1, South City Business Centre, Tallaght, Dublin 24, Ireland.
Telephone: +353 1 466 2570. Telefax: +353 1 452 0427. E-mail: sales@accesscontrol.ie Web: www.accesscontrol.ie
Telephone: +353 1 466 2570. Telefax: +353 1 452 0427. E-mail: sales@accesscontrol.ie Web: www.accesscontrol.ie
Wiring for Entry/Exit Readers
ACTProX Product Range
1030/1040/1050/1060
ProX
The ACTProX Range of Readers can read HID
Clock & Data format, HID 26-Bit Wiegand format
and the ACTSmart2 format.
Clock/Data 1
Data/Data 0
5v
0v
Red LED
Green LED
Connect the SENSE line to the Controller if you require an
Entry Reader. Leave the SENSE line unconnected for an
Exit Reader or for operation with Wiegand Cards.
Internal buzzer is
activated by applying
0V to Buzz Ctrl (Orange Wire)
Wire both readers in parallel but connect D0
line of the exit reader into the SENSE line on
the controller,leave the SENSE line on the
Exit reader unconnected.