HP 2520g-poe Benutzerhandbuch

Seite von 101
2-20
Installing the Switch
Installation Procedures
For mini-GBIC ports, and in general for all the switch ports, when a network 
cable from an active network device is connected to the port, the port LED 
for that port should go on. If the port LED does not go on when the network 
cable is connected to the port, see 
 in chapter 4, 
“Troubleshooting”.
7. (Optional) Connect a Console to the Switch
The 2520G-PoE switches have a full-featured, easy to use console interface 
for performing switch management tasks including the following:
monitor switch and port status and observe network activity statistics
modify the switch’s configuration to optimize switch performance, 
enhance network traffic control, and improve network security
read the event log and access diagnostic tools to help in troubleshooting
download new software to the switch
add passwords to control access to the switch from the console, Web 
browser interface, and network management stations
The console can be accessed through these methods:
Out-of-band:
 The 2520G-PoE switches come with a serial cable for 
connecting a PC or VT-100 terminal, to be used as a console, directly to 
the switch.
In-Band:
 Access the console using Telnet from a PC or UNIX station on 
the network, and a VT-100 terminal emulator. This method requires that 
you first configure the switch with an IP address and subnet mask by using 
either out-of-band console access or through DHCP/Bootp. For more 
information on IP addressing and on starting a Telnet session, see 
chapter 3, 
, in the Management and 
Configuration Guide
, which is on the ProCurve Web site at
.
The 2520G-PoE switches can simultaneously support one out-of-band console 
session through the Console Port and in-band Telnet console sessions.
Terminal Configuration
To connect a console to the switch, configure the PC terminal emulator as a 
DEC VT-100 (ANSI) terminal or use a VT-100 terminal, and configure either 
one to operate with these settings:
any baud rate from 1200 to 115200 (the switch senses the speed)
8 data bits, 1 stop bit, no parity, and flow control set to Xon/Xoff
for the Windows Terminal program, also disable (uncheck) the “Use 
Function, Arrow, and Ctrl Keys for Windows” option