HP kp721av Benutzerhandbuch

Seite von 120
Technical Reference Guide
www.hp.com
8-5
SYSTEM BIOS
8.4  Client Management Functions
Table 8-2 provides a partial list of the client management BIOS functions supported by the 
systems covered in this guide. These functions, designed to support intelligent manageability 
applications, are HP-specific unless otherwise indicated.
NOTE:
[1] Industry standard function.
All 32-bit protected-mode functions are accessed by using the industry-standard BIOS32 Service 
Directory.  Using the service directory involves three steps:
1. Locating the service directory.
2. Using the service directory to obtain the entry point for the client management functions.
3. Calling the client management service to perform the desired function.
The BIOS32 Service Directory is a 16-byte block that begins on a 16-byte boundary between the 
physical address range of 0E0000h-0FFFFFh.
The following subsections provide a brief description of key Client Management functions.
Table 8-2.
Client Management Functions (INT15)
AX
Function
Mode
E800h
Get system ID
Real, 16-, & 32-bit Prot.
E813h
Get monitor data
Real, 16-, & 32-bit Prot.
E814h
Get system revision
Real, 16-, & 32-bit Prot.
E816h
Get temperature status
Real, 16-, & 32-bit Prot.
E819h
Get chassis serial number
Real, 16-, & 32-bit Prot.
E820h [1] Get system memory map
Real
E81Ah
 Write chassis serial number
Real
E827h
DIMM EEPROM Access