Power Requirement
Power Requirement
Power Requirement
Power Requirement
 
MSL6030/26 Tape Library
MSL6030/26 Tape Library
MSL6030/26 Tape Library
MSL6030/26 Tape Library
MSL6060/52 Tape Library
MSL6060/52 Tape Library
MSL6060/52 Tape Library
MSL6060/52 Tape Library
Typical
180 Watts
300 Watts
Maximum
240 Watts
440 Watts
Robotics Performance
Robotics Performance
Robotics Performance
Robotics Performance
 
MSL6030/26 Tape Library
MSL6030/26 Tape Library
MSL6030/26 Tape Library
MSL6030/26 Tape Library
MSL6060/52 Tape Library
MSL6060/52 Tape Library
MSL6060/52 Tape Library
MSL6060/52 Tape Library
Initialization time
100 sec
240 sec
Inventory time
60 sec
110 sec
Cartridge swap
(drive to slot)
8 sec average
15 sec average
NOTE:
NOTE:
NOTE:
NOTE: 35 sec average cartridge
swap time for 4 scaled modules.
Relative Humidity (non-
Relative Humidity (non-
Relative Humidity (non-
Relative Humidity (non-
condensing)
condensing)
condensing)
condensing)
Operating
10 to 80% @ 82° F (28° C)
 
Shipping
10 to 90% @ 82° F (28° C)
 
Temperature Range
Temperature Range
Temperature Range
Temperature Range
Operating
50° to 95° F (10° to 35° C)
 
Shipping
-40° to 140° F (-40° to 60° C)
 
© Copyright 2006 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Windows NT is a US registered trademark of Microsoft Corporation. Unix is a registered trademark of The Open Group.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial
errors or omissions contained herein.
QuickSpecs
HP StorageWorks MSL6000 Tape Library
HP StorageWorks MSL6000 Tape Library
HP StorageWorks MSL6000 Tape Library
HP StorageWorks MSL6000 Tape Library
Technical Specifications
DA - 11863   Worldwide — Version 24 — July 7, 2006
Page 18