Canon galvano gc-251 Benutzerhandbuch
![Canon](https://files.manualsbrain.com/attachments/4b6818c07b947b910f8cfb49338c2c63bdefaee1/common/fit/150/50/61ea34cb812b6780fe3b16f0b9221bd2f7635c65cee2473b66396d8b72cd/brand_logo.png)
CANON Digital Galvano Scanner System
KP-1SM Series + GC-251
Users Manual 1.00
49
【Input the external trigger signal】
The external trigger signal is input from the digital I/O connector.
(
See 5-1 ‘Connector Pin Arrangement)
Connector pin arrangement
Pin
NO.
Monitor Board
Signal Name
I/O Signal
Description Logic Remarks
B5
D
10 Input
External
Trigger
Signal High:ON
See Circuit below.
Connection Specifications
3.3V TTL Input
【Operation procedure】
(Raster Scan Parameter Settings)
・
Set Parameter ID =26
Raster Scan Time
・
Set Parameter ID =27
Raster Scan Duty Ratio
・
Set Parameter ID =28
Raster Scan Angle
(Raster Scan Operation)
・
Send Command ID=8 Data=6 Movement Start (Movement to the Initial position
of raster scan)
・
Send Command ID=23 Data=8 (One way scan)
Data=9 (One coming and going)
(Reference: Data =3 in case of continuous operation)
・
Input the external trigger Signal
・
Send Command ID=23 Data=0 Scan Stop
【Notes】
・
The external trigger input during raster scan move is ignored.
・
10usec or less is uneven from the external trigger signal input at time until beginning to
・
actually operate.
FPGA
3.3V-TTL
R : 100Ω
Connector
Select either