HDS-X5800
Status of the entire system
Ref. No.
(Address)
LED name
Status when lights up
D701
(G-8)
ACTIVE
Control is executed. (The CPU-339 board on which D701 lights up
is mainly running.)
D702
(G-8)
REMOTE1 B
REMOTE1 B1 or B2 is set to the primary station.
PRIMARY ON
D703
(G-8)
RUN
The program on the CPU-339 board is running correctly.
D704
(G-8)
ERROR
An abnormality is detected by the self-diagnostics.
n
Error code is indicated on ND701 to ND703.
ND703
(G-8)
ERROR No. 7SEG
When an abnormality is detected by the self-diagnostics, its error
ND702
(G-8)
code is indicated.
ND701
(G-8)
(For details of the error code, refer to Section 2-3.)
Status of the data link that is connected to DATA LAN (DATA connector)
Ref. No.
(Address)
LED name
Status when lights up
D403
(H-8)
ACT
Sending data to the data link or receiving data from the data link.
D402
(H-8)
LINK
Being connected to the data link.
D401
(H-8)
100/10
Equipment on the data link is operating on 100BASE-TX.
Status of others
Ref. No.
(Address)
LED name
Status when lights up
D1308
(A-5)
+3 V
Power supply circuit supplying 
+3.3 V is operating.
D1307
(B-5)
+5 V
Power supply circuit supplying 
+5 V is operating.
D201
(F-7)
_
Factory use.
ND302
(J-6)
LEFT
Factory use.
ND301
(J-6)
RIGHT
Factory use.
D301
(J-6)
M7
Factory use.
D302
(J-6)
M6
Factory use.
D303
(J-6)
M5
Factory use.
D304
(J-6)
M4
Factory use.
1-11. Setting the On-Board Switches and Description of LEDs