When IMMED. CAP. is set to OFF:
The above example shows that the images at the seventh 
and eighth positions are captured. However, images at 
other positions could be captured depending on the 
printer mode and printer settings.
Note
When AUTO LIVE of the FUNCTION SETUP menu is 
set to OFF, the memory image is displayed on the screen 
after the image is captured in memory. In such a case, 
whenever you capture an image, press the SOURCE/
MEMORY button so that the source image appears on 
the video monitor. Displaying the memory image does 
not allow you to capture the image with the correct 
timing.
When IMMED. CAP. is set to ON:
Note
This mode is effective only when the source image is 
displayed on the monitor screen. If the memory image is 
displayed, the image will not be captured even if the 
pulse is sent to the printer. Be sure to display the source 
image when sending the pulse.
Design and specifications are subject to change without 
notice.
Notation
Parameter
MIN TYP MAX Unit Remarks
tRPE
Time within 
which a remote 
control pulse 
should be cleared 
to zero.
3
-
12
msec -
tRPW
Length of a 
remote control 
pulse
100
-
-
msec -
VRP
Amplitude of a 
remote control 
pulse
-
-
5
V
This value is 
based on the 
TTL standard.
Remote control 
pulse signal
Captured image
Notation
Parameter
MIN TYP MAX Unit Remarks
tRPE
Time within 
which a remote 
control pulse 
should be cleared 
to zero.
3
-
10
msec -
tRPW
Length of a 
remote control 
pulse
100
-
-
msec -
VRP
Amplitude of a 
remote control 
pulse
-
-
5
V
This value is 
based on the 
TTL standard.
Captured image
Remote control 
pulse signal