Nokia n-gageqda Servicehandbuch

Seite von 12
Nokia Customer Care
1 - General Information
                                 Company Confidential
      RH-47
Issue 1 05/04 
        Copyright ©
 2004 Nokia Corporation
Page 9
Company Confidential
General Specifications of Transceiver RH-47
Environmental conditions
Parameter
Unit
Cellular system
GSM850, GSM1900
RX frequency band
GSM850: 869 -894 MHz
GSM1900: 1930 - 1990 MHz
TX frequency band
GSM850: 824 - 849 MHz
GSM1900: 1850 - 1910 MHz
Output power
GSM850: +5...+33 dBm/3.2 mW...2W
GSM1900: +0...+30 dBm/1.0mW...1W:
Number of RF channels
GSM850: 124
GSM1900: 300
Channel spacing
200 kHz
Number of TX power levels
GSM850: 15
GSM1900: 16
Environmental condition
Ambient 
temperature
Notes
Normal operation
-10
o
C...+55
o
C
Specifications fulfilled
Reduced performance
+55 C...+65 C
Operational only for short periods
Intermittent operation
-20 C...-10 C and
 +65 C...+85 C
Operation not guaranteed but an attempt to operate does 
not damage the phone.
No operation
-40 C...-20 C
Operation not guaranteed but an attempt to operate does 
not damage the phone.
No operation or storage
<-40 C and > +85 C
No storage; an attempt to operate may cause permanent 
damage.
Charging allowed
-25 C...+60 C
Long term storage conditions
0 C...+40 C