Initialization Pulse Adjustment
1. Input a 100% White signal to the unit.
2. Set the picture controls as follows:
Picture menu : Vivid
Normal : Set
Aspect : Full
3. Connect an Oscilloscope to test point TPSC1. Using VR6602, adjust (T2) for 195+/- 
10µ Sec.
97