Panasonic AG-MX70 Benutzerhandbuch

Seite von 102
56
[Setup] initial setting screen
System1
Dly
1Frame
Time
Sec
GPI
ME
RS422
GVG
1Frame
0Frame
Sec
Frame
ME
DSK
Fade
GVG
SONY
System2
LCDStby
0
VBClean
Off
DR
On
0 - 60
On
Off
On
Off
[System1] setting
This is used to perform a variety of settings.
The rotary 2 control is used to set the amount of delay for
the source input when the [AdvRef] advanced reference
signal is connected with the 3D optional board (AG-VE70)
installed.  If 0Frame is selected, the video delay amount is
different between when the 3D effects are applied and when
they are not.  The default setting is 1Frame.  The setting is
fixed at 0Frame when the 3D optional board is not installed.
The audio source delay amount is also set according to this
setting.
[Sec] (seconds + frames) or [Frame] (frames) only is
selected for the time display using the rotary 3 control.  The
default setting is [Sec].
[System2] setting
The time taken until the LCD is set to the power saving
mode can be selected using the rotary 2 control.
With the 0 setting, the display is always on.  The time can
be set in 10-minute increments from 0 to 60.  The default
setting is 0.
[On] or [Off] is selected using the rotary 3 control to set
whether or not cleaning is to be performed inside the vertical
blanking period (VBlk).  The default setting is [Off].
Bus
Type
AB
Still
On
Tally
8
Audio
CP
AB
Prg Pre
On
Off
8
EXT
CP
1, 2
[Bus] setting
AB (AB bus) or PrgPre (program/preset system) can be
selected as the bus system using the rotary 2 control.  The
default setting is AB.
[On] (initiate Still) or [Off] (do not initiate Still) when cross
points are to be changed is selected using the rotary 3
control.  The default setting is [On].
The Audio MIX system can be selected using the rotary 4
control.
Whether [ME], [DSK] or [Fade] is to be executed by GPI can be set using the rotary 4 control.  The default setting is [ME].
[GVG] or [SONY] can be selected as the RS-422A protocol using the rotary 5 control.  The default setting is [GVG].
[On] or [Off] is selected using the rotary 4 control to set whether or not the [DR] (dynamic rounding) is to be performed.  The
default setting is [On].
<Note>
Selecting [Off] for [VBClean] may result in a deviation in the amount of delay between the video signals and vertical blanking
signals depending on the setting for the [Dly] item among the [System1] settings and on whether the 3D optional board (AG-
VE70) has been installed.
R1
R2
R3
R4
R5
R1
R2
R3
R4
R5
R1
R2
R3
R4
R5
At the [CP] setting, two audio sources allocated to the selected cross point are output. At the [1,2] setting, the audio sources
1, 2 allocated to the cross point are mixed at all times.  The default setting is [CP].
[8] or [EXT] can be selected using the rotary 5 control as the setting for the eight tally outputs. At the [8] setting, the tally
signal is output when cross point 8 has been selected; at the [EXT] setting, it is output when EXT has been selected.
<Note>
When [Still] is to be set to [Off], do not mix the analog and SDI signals for the input. Be absolutely sure to use the analog-only
system or SDI-only system.