Panasonic ag-tl750 Benutzerhandbuch

Seite von 58
15
3-2  System Using Sequential Switcher
1
Connect video cameras and alarm sensor to a sequential switcher (frame switcher).
2
Connect the sequential switcher’s (frame switcher) alarm signal output, camera switching signal input and video output to
the AG-TL750B/E.
3
Connect the monitor’s video/audio input connectors to the AG-TL750B/E’s video/audio output connectors.
4
When the connection is complete, connect the mains plug to an AC 220 V-240 V, 50 Hz/60 Hz socket.
5
Synchro should be applied to all connected video cameras.
6
When connecting the camera switching signal input terminal of the sequential switcher (frame switcher) to the AG-TL750B/
E, set the menu switch <CAMERA SW>.
3  CONNECTIONS
Video camera
Alarm sensor input
Alarm sensor
Microphone
Sequential switcher
Amplifier
Monitor TV
AC 220 V-240 V
50 Hz/60 Hz
Provided
power cable
ALARM IN
Video output
Phono
Phono
BNC
Camera switching
signal input
Alarm signal output
CAM SW
OUT
4-pin
1                       2                    3                   4                       5                   6
1             2             3              4             5             6
SPARE
MIC
IN
OUT
AUDIO
VIDEO
R S - 2 3 2 C
CAM SW
OUT
ALARM
IN
COM
COM
ALARM
REC OUT
ALARM
RESET
TAPE
END OUT
WARNING
OUT
CLOCK
RESET  IN
SERIES
REC  IN
SERIES
REC  OUT
CLOCK
RESET  OUT
AC~IN
S-VIDEO
BNC