Panasonic ag-tl750 Benutzerhandbuch
15
3-2 System Using Sequential Switcher
1
Connect video cameras and alarm sensor to a sequential switcher (frame switcher).
2
Connect the sequential switcher’s (frame switcher) alarm signal output, camera switching signal input and video output to
the AG-TL750B/E.
the AG-TL750B/E.
3
Connect the monitor’s video/audio input connectors to the AG-TL750B/E’s video/audio output connectors.
4
When the connection is complete, connect the mains plug to an AC 220 V-240 V, 50 Hz/60 Hz socket.
5
Synchro should be applied to all connected video cameras.
6
When connecting the camera switching signal input terminal of the sequential switcher (frame switcher) to the AG-TL750B/
E, set the menu switch <CAMERA SW>.
E, set the menu switch <CAMERA SW>.
3 CONNECTIONS
Video camera
Alarm sensor input
Alarm sensor
Microphone
Sequential switcher
Amplifier
Monitor TV
AC 220 V-240 V
50 Hz/60 Hz
50 Hz/60 Hz
Provided
power cable
power cable
ALARM IN
Video output
Phono
Phono
BNC
Camera switching
signal input
signal input
Alarm signal output
CAM SW
OUT
OUT
4-pin
1 2 3 4 5 6
1 2 3 4 5 6
SPARE
MIC
IN
OUT
AUDIO
VIDEO
R S - 2 3 2 C
CAM SW
OUT
ALARM
IN
COM
COM
ALARM
REC OUT
ALARM
RESET
RESET
TAPE
END OUT
WARNING
OUT
CLOCK
RESET IN
SERIES
REC IN
REC IN
SERIES
REC OUT
CLOCK
RESET OUT
AC~IN
S-VIDEO
BNC