Panasonic AJ-HD150 Benutzerhandbuch

Seite von 102
– 64 –
Setup menus
USER menu
<TAPE PROTECT>
Item
Setting
No.
Superimposed
No.
Superimposed
Description
display
display
400
STILL
0000
0.5s
TIMER
0001
5s
0002
10s
0003
20s
0004
30s
0005
40s
0006
50s
0007
1min
0008
       2min
401
SRC
0000
       STEP
PROTECT
0001
HALF
402
DRUM
0000
OFF
STDBY
 0001
          ON
403
STOP
0000
STEP
PROTECT
0001
      HALF
The underline on the setting item denotes the initial setting.
<Note>
The cumulative standby time at the same tape position increases when transmitting
programs or otherwise using identical materials repeatedly.
This selects the time to be taken until the unit goes into the tape
protection mode when it is left standing in the stop or search still
(JOG/VAR/SHTL) mode. (Unit: s = second, min = minute)
This selects the operation during the tape protection mode
when the unit is left standing in the still status during the
search mode (JOG/VAR/SHTL).
0: STEP FWD.
1: HALF LOADING.
<Note>
When STEP FWD is selected, the unit automatically goes into
the HALF LOADING mode when the total time for which the
unit is left standing in the still status reaches 30 minutes.
This selects the drum operation in the STANDBY OFF mode.
0: The drum stops rotating.
1: The drum continues rotating.
This selects the operation in the tape protection mode when
the unit has been left standing in the STOP mode.
0: STEP FWD
1: HALF LOADING
<Note>
When STEP FWD is selected, the unit is automatically
transferred to the HALF LOADING mode when the total time
during which it has been left standing in the STOP mode
reaches 30 minutes.
Setup menus