Panasonic AJ-SPX800E Benutzerhandbuch

Seite von 118
89
7
7-3
Warning System
7-3-1
Warning Description Tables
If a problem is detected immediately after the power is turned on, or during operation, this will be indicated by the WARNING lamp, 
lamps inside the viewfinder and a warning tone. 
<Note>
The WARNING lamp has the highest priority, followed by the tally lamp, and then the warning tone. When multiple errors occur 
simultaneously a higher priority indication will be triggered. The [WIRELESS RF], however, may not be indicated, depending on the 
menu setting. 
1. System Errors
Display window 
indication 
The error code lights up.
WARNING lamp 
Blinks 4 times per second. 
Tally lamp
Blinks 4 times per second. 
Viewfinder
The SYSTEM ERROR indication and the error
code light up. 
Warning tone
Beeps continuously. 
Warning 
description 
An error in the reference signal or the
communication. 
Recording/
playback operation 
The operation stops. 
Countermeasures
Please confirm [7-3-2 Error Codes] and consult
your nearest service centre. 
3. Battery Empty
Display window 
indication 
All 7 bar indicators for battery remaining capacity
start blinking. 
WARNING lamp 
Lights up. 
Tally lamp
Blinks once per second. 
Viewfinder
The BATT LED lights up. 
Warning tone
Beeps continuously. 
Warning 
description 
The battery has run out. 
Recording/
playback operation 
The operation stops. 
Countermeasures
Replace the battery. 
2. 
Card removal error
Display window 
indication 
Error code E-30 appears.
WARNING lamp 
Blinks 4 times per second.
Tally lamp
Blinks 4 times per second.
Viewfinder
The “TURN POWER OFF” indicator blinks.
Warning tone
Continues to beep.
Warning 
description 
The P2 card being accessed has been removed,
resulting in an error in the internal memory of the
camera-recorder.
Recording/
playback operation 
Cannot be performed.
Countermeasures
Turn off the power to the camera-recorder. If
there is an error in a clip on the removed P2 card,
repair the clip.
4. Write-protect
Display window 
indication 
All 7 bar indicators for remaining MEDIA capacity
start blinking. 
WARNING lamp 
Continues to light up until an operation is
performed. 
Tally lamp
Continues to blink 4 times per second until an
operation is performed. 
Viewfinder
The WP indicator blinks. 
Warning tone
Continues to beep until an operation is
performed. 
Warning 
description 
The inserted P2 cards are write-protected. 
Recording/
playback operation 
Recording is disabled. 
Countermeasures
Disable the write-protect or replace the P2 card.