Panasonic KX-TGP500 Benutzerhandbuch

Seite von 252
Default Value
Empty string
Web User Interface Reference
REG_EXPIRE_TIME_[1–8]
Parameter Name Example
REG_EXPIRE_TIME_1REG_EXPIRE_TIME_2, …,
REG_EXPIRE_TIME_8
Value Format
Integer
Description
Specifies the length of time, in seconds, that the registration remains
valid. This value is set in the "Expires" header of the REGISTER
request.
Value Range
1–4294967295
Default Value
3600
REG_INTERVAL_RATE_[1–8]
Parameter Name Example
REG_INTERVAL_RATE_1REG_INTERVAL_RATE_2, …,
REG_INTERVAL_RATE_8
Value Format
Integer
Description
Specifies the percentage of the "expires" value after which to refresh
registration by sending a new REGISTER message in the same dialog.
Value Range
1–100
Default Value
90
SIP_SESSION_TIME_[1–8]
Parameter Name Example
SIP_SESSION_TIME_1SIP_SESSION_TIME_2, …,
SIP_SESSION_TIME_8
Value Format
Integer
Description
Specifies the length of time, in seconds, that the unit waits before
terminating SIP sessions when no reply to repeated requests is
received. For details, refer to RFC 4028.
Value Range
0, 60–65535 (0: Disable)
Default Value
0
Web User Interface Reference
TOS_SIP_[1–8]
Parameter Name Example
TOS_SIP_1TOS_SIP_2, …, TOS_SIP_8
Document Version    2010.03.15
Administrator Guide
181