Panasonic MDDDT5540 Benutzerhandbuch

Seite von 133
- App.17 -
Appendixes
P r N o .
P a r a m e t e r
Value
F u n c t i o n
0 2
(continued)
Control  mode
set-up
( c o n t i n u e d )
* Example  of  4  speeds  operation  using  internal  velocity  command
In  addition  to  DIV/INTSPD1  and  CL/INTSPD2,  zero  speed  clamp
input  (ZEROSPD)  and  Servo-On  input  (SRV-ON)  are  required  as
the  input  to  control  start  and  stop  of  the  motor.
< N o t e s >
Acceleration  time,  deceleration  time  and  S-shaped  acceleration/
deceleration  time  can  be  set  individually.
Refer  to  the  descriptions  of
Pr58:    Acceleration  time  set-up
Pr59:    Deceleration  time  set-up
Pr5A:    S-shaped  acceleration/deceleration  time  set-up
SRV-ON input
Servo-On
Operation
Stop
Velocity
OPEN
OPEN
1st speed
2nd speed
3rd speed
4th -speed
Time
OPEN
CLOSE
CLOSE
CLOSE
CLOSE
OPEN
ZEROSPD input
DIV/INTSPD1 input
CL/INTSPD2 input