Replacing
1. Turn off the MAIN POWER switch according to the procedure 
“Switching the projector on/off” on page 19, and then disconnect the 
power cord plug from the wall outlet and check that the area around 
the lamp unit has cooled down.
2. Use a Phillips screwdriver to turn the lamp unit cover fixing screws at 
the bottom of the projector, and then remove the lamp unit cover.
3. Use a Phillips screw driver to loosen the two lamp unit fixing screws 
until the screws turn freely. Then hold the handle of the lamp unit and 
gently pull it out from the projector.
4. Insert the new lamp unit while making sure that the direction of 
insertion is correct, and then use a Phillips screwdriver to securely 
tighten the lamp unit fixing screw.
5. Install the lamp unit cover, and then use a Phillips screwdriver to 
securely tighten the lamp unit cover fixing screws.
Resetting the LAMP RUNTIME
If the lamp usage time has passed 2 000 hours (when LAMP POWER has been set to NORMAL), the 
projector will switch to standby mode after approximately 10 minutes of operation. The resetting procedure 
should thus be completed within 10 minutes.
1. Insert the power cord plug into the wall outlet and then 
press the MAIN POWER switch.
2. Press the POWER button so that a picture is projected onto 
the screen.
3. Press the MENU button to display the menu screen, and 
then press the 
F or G button to select the OPTION menu.
4. Press the ENTER button, and then press the 
F or G button 
to select LAMP RUNTIME.
5. Press and hold the ENTER button for approximately 
3 seconds. The confirmation screen, “LAMP RUNTIME 
RESET.
” is displayed and select OK.
6. Turn off the power.
  This will reset the cumulative usage time for the lamp 
unit to zero.
Replacing the lamp unit
NOTE:
  Be sure to install the lamp unit and the lamp unit cover securely. If they 
are not securely installed, it may cause the protection circuit to operate so 
that the power cannot be turned on.
  Grip the handle when you remove the lamp unit. Some parts of the lamp 
unit are sharpened and may cause injury.
Lamp unit fixing screws
Handle
Press 
here
Press 
here
Lamp unit cover
Lamp unit cover fixing screws
1820H
NORMAL
LOW
OFF
FRONT/DESK
NORMAL
ON
ON
BLUE
CENTRE
TYPE1
DETAILED
LAMP RUNTIME
TEST PATTERN
LAMP POWER
ALTITUDE
SLEEP
INSTALLATION
HDMI SIGNAL LEVEL
AUTO SEARCH
STARTUP LOGO
BACK COLOUR
OSD POSITION
OSD DESIGN
INPUT GUIDE