Suggestions: Check the 
Scan pulse waveform at 
TPSC1 of the SC-Board. 
(Use TPSS1 of the SS-
board to trigger the 
oscilloscope.) Proceed to 
check the power sources at 
connector SS11, SS12 and 
SS33. 
Verify that the clock and 
serial data lines from the D-
board are present at 
connector SS33. 
 
Note: It is easier to 
measure input levels at 
connector C33 of the C3-
Board instead of connector SS33. 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 40