9.4 
Power Range 1000-3000 VA (230 V) 
Tower 
International 
230V Model 
UT1E1E010C6 
UT1E1E015C6 
UT1E1E020C6 
UT1E1E030C6 
Rack- 
mount (2U) 
International 
230V Model 
UT1E1E010C6
RKB2 
UT1E1E015C6
RKB2 
UT1E1E020C6
RKB2 
UT1E1E030C6RKB
Input 
Voltage 
(International) 
230 VAC (161 – 276 V) 
 
Voltage Range 
(International) 
+20% to -30% 
 
Frequency 
50 / 60 Hz auto sensing 
 
Power Factor 
Greater than 0.97 
 
Topology 
True on-line, Double conversion Input PF correction 
Output 
Voltage 
(International) 
230 VAC 
 
Capacity (VA) 
1000 VA 
1500 VA 
2000 VA 
3000 VA 
 
Capacity (W) 
700 W 
1050 W 
1400 W 
2100 W 
 
Frequency 
50 / 60 Hz auto sensing* 
 
Wave Form 
Sine wave, zero transfer time 
 
Load Power 
Factor 
0.7 
 
Efficiency 
AC/DC/AC 
Greater than 86% 
Greater than 85% 
 
Rated Current 
(International) 
4.3 A 
6.5 A 
13 A 
13 A 
 
Overload 
Capacity 
125% for 1 min., 150% for 10 sec. 
125% for 1 min., 
130% for 10 sec. 
 
Crest Factor 
3.0 at full load 
2.5 at full load 
Battery 
DC Voltage 
(Tower & 2U) 
36 V / 12 V  
9 AH x 3 
72V / 12 V  
9 AH x 6 
 
Backup Time 
(Tower & 2U) 
7 min  
(full load) 
6 min  
(full load) 
5 min  
(full load) 
5 min  
(full load) 
 
Interface 
RS-232 and USB standard RemotEye II® and EMD option 
Physical 
Dimensions 
(Tower) 
16.5”L x 6.0”W x 9.4”H 
16.7" L x 8.9" W 
x 14.2" H 
16.7" L x 8.9" W x 
14.2" H 
 
Dimensions 
(2U) 
16.7”L x 16.9”W x 3.5”H 
25.0"L x 16.9"W 
x 3.5"H" 
25.0"L x 16.9"W x 
3.5"H" 
 
Weight 
(Tower/2U) 
35.6 lbs / 
37.6 lbs 
37.4 lbs / 
37.6 lbs 
68.4 lbs / 
69.5 lbs 
72.6 lbs / 71.5 lbs 
 
Line Cord 
(International) 
IEC 320 
 
Receptacles 
(Tower/2U) 
International  
IEC 320 (4 / 4) 
IEC 320 (8 / 4) 
IEC 320 (8 / 4) 
Environ- 
ment 
Operating 
Temperature 
32 – 104°F (0 – 40°C) 
 
Altitude 
11,500 ft (3500 m) above sea level 
Warranty 
 
Three years on electronics 
Two years full replacement on battery (See Toshiba warranty policy for full details.) 
Output frequency can hard set at 50 or 60 Hz by installing an optional software upgrade.  This upgrade enables the user to 
select a fixed output frequency and simultaneously disables the bypass mode. 
Standards - Safety: EN 62040-1, Emissions: EN 62040-2, Immunity: EN 62040-2 Category C1 (1000-2000VA), EN 62040-2 
Category C2 (2000-3000VA