Toshiba surveillix kv-klr Benutzerhandbuch

Seite von 124
 
14
   
2.8 
Connecting Control Outputs to the DVR 
 
 
 
Each DVR unit may have up to 16 Control Outputs. These outputs can be used to trigger devices such as Sirens, 
Phone Dialers, Lights, and any other relay activated device. 
 
Control Output 
 
 
 
 
 
 
 
 
 
 
 
   
• 
Use 12V, below 300mA. For controlling lights or other devices, use another external relay. 
• 
Maximum voltage is 24V AC @ 1 amp 
• 
Output uses a Form C Relay 
 
External Power Supply ( DC 12V) 
Common 
Relay (1 ~ 4) 
(+) 
Siren, Alarm, Outside Relays 
(-)