Siemens MC35 Benutzerhandbuch

Seite von 256
AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 190 of 256 
15.07.2002 
 
8.5 AT^SBC  Battery charging / discharging and charge control 
This chapter is only applicable to MC35, it is not intended for MC35 Terminal.  
 
Responses returned by the AT^SBC command vary with the operating mode of the ME: 
Normal mode: 
 
ME is switched on by Ignition pin and running the SLEEP, IDLE, 
TALK or DATA mode. Charger is not connected. AT^SBC can be 
used to query the battery capacity and the power consumption of 
ME and application (if value of application was specified before as 
<current>). 
Normal mode + charging:  
Allows charging while ME is switched on by Ignition pin and running 
the SLEEP, IDLE, TALK or DATA mode. AT^SBC returns charger 
status and power consumption of ME / application. Battery capacity 
is not available. 
Charge-only mode: 
Allows charging while ME is detached from GSM network. When 
started, the mode is indicated by the URC "^SYSSTART CHARGE-
ONLY MODE". AT^SBC returns charger status and power consump-
tion of ME / application. Percentage of battery capacity is not avail-
able. In Charge-only mode a limited number of AT commands is ac-
cessible (see Table 11). There are several ways to activate the 
Charge-only mode: 
 
 
 
a) from Power Down mode: Connect charger while ME was powered 
down with AT^SMSO 
 
 
 
b) from Normal mode: Connect charger, then enter AT^SMSO. 
Alarm mode: 
 
No charging functionality, i.e. charging does not start even though 
the charger connects to the POWER lines. Battery parameters are 
not available. 
 
Charging begins once the charger connects to the POWER pins of the ZIF connector (except for the 
Alarm mode). Please refer to the [1] for details on the charging process. 
 
Test command 
AT^SBC=? 
Response 
^SBC: (list of supported <bcs>s),(list of supported <bcl>s),<mpc>  module power 
consumption  
Defined values 
<bcs
No charging adapter is connected 
 
Charging adapter is connected 
 
Charging adapter is connected, charging in progress 
 
Charging adapter is connected, charging has finished 
 
Charging error, charging is interrupted 
 
False charging temperature, charging is interrupted while 
temperature is beyond allowed range 
 
<bcl>  
Battery capacity 
0, 20, 40, 60, 80, 100 percent of remaining capacity (6 steps)  
 
0 indicates that either the battery is exhausted or the capacity value 
is not available 
 
<mpc> 
Average power consumption: 
Value (0...5000) of average power consumption (mean value over a 
couple of seconds) in mA. See read and write command for details.