Alliance Laundry Systems T433I Benutzerhandbuch

Seite von 116
Installation
M414038
26
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Model 120FG
INPUT: 87.8 kW
Table 2 
NOTE: In addition to directions below, follow all 
instructions including verification and adjustment 
of injector pressure.
– Order as Regulated Natural Gas. No modification 
needed.
– Order as Regulated Natural Gas. Apply 
appropriate country sticker.
– Order as Regulated Natural Gas. Apply 
appropriate country and gas stickers.
– Order as Unregulated with Unregulated Natural 
Gas injectors. Apply appropriate country sticker.
– Order as Unregulated with L.P. Gas injectors. 
Apply appropriate country sticker.
– Order as Regulated Natural Gas. Convert with 
(3) 2.6 mm injectors Part No. M411376. Apply 
appropriate country and gas stickers.
 Order as Unregulated with L.P. Gas injectors. No 
modification needed.
– Order as Unregulated with L.P. Gas injectors. 
Apply appropriate country sticker.
OPEN – No Approval available.
Special Cases  No additional kits are required to 
convert from regulated to unregulated.
Gas
Type
GB
IE
PT
ES
IT
DK
NO
SE
FI
DE
NL
BE
FR
AT
Gas 
Family 
& Group
Inject. 0
Inject. Qty 
& Part. No.
Inlet 
Press.
Gvnr./
Regltr.
Inject. 
Press.
Nat.
Gas
1
1
1
1
1
2
2
2
2
2
2
2nd 
family 
Group H 
(E)
4.8 mm
3
M411372
20 mbar
Yes
8.9 mbar
3
2nd 
family 
Group L 
(LL)
4.8 mm
3
M411372
25 mbar
Yes
12.0 
mbar
4
4
2nd 
family 
Group E+
4.2 mm
3
M402295
20.25 
mbar
No
Unreg.
L.P. 
Gas
5
5
5
5
5
5
3rd 
family 
Group 
B/P
2.6 mm
3
M411376
30 mbar
No
Unreg.
6
6
3rd 
family 
Group 
B/P
2.6 mm
3
M411376
50 mbar
Yes
26.4 
mbar
7
7
7
7
7
8
8
3rd 
family 
Group 3+
2.6 mm
3
M411376
28.37 
mbar
No
Unreg.