Sub-Zero 48gasrangetop Benutzerhandbuch

Seite von 5
Planning Information
48"
(1219)
Gas Rangetops
M O D E L S   R T 4 8 8   /   R T 4 8 6 C   /   R T 4 8 6 G   /   R T 4 8 4 C G   /   R T 4 8 4 D G   /   R T 4 8 4 F   /   R T 4 8 2 C F
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications
for overall dimensions, finished rough opening
dimensions and installation specifics.
IMPORTANT NOTE: Caution must be used in
planning the proper installation of the Wolf gas
rangetop to avoid any fires or damage to
adjacent cabinetry or kitchen equipment. Please
follow the minimum clearances established in
the finished rough opening dimensions as
shown in the Installation illustration.
IMPORTANT NOTE: In non-island applications,
a riser is required when installing a 48" (1219)
gas rangetop against a combustible surface.
It is recommended that you use a Wolf Pro
wall or island ventilation hood or hood liner
with the Wolf gas rangetop. Pro Ventilation
information can be found on our website,
wolfappliance.com. Also refer to the Wolf
Design Guide for Pro ventilation recommenda-
tions.
The Wolf gas rangetop requires a 110 /120 V
AC, 60 Hz electrical supply to operate the elec-
tronic ignition system. The 6' (1.8 m) power
supply cord provided with the rangetop is
equipped with a 3-prong, grounded plug for
protection against shock hazard. The service
should have its own 15 amp circuit breaker.
Locate electrical and gas supply within the
shaded area shown in the Installation illustra-
tion.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
Wolf gas rangetops are designed to operate
on natural gas at 5" (12.5 mb) WC (water
column) pressure or LP (propane) gas at 10"
(25 mb) WC pressure. The minimum line
pressure for natural gas is 7" (17.5 mb) WC and
11" (27.4 mb) WC for LP gas. The maximum gas
supply pressure to the regulator should never
exceed 14" (34.9 mb) WC; .5 psi (3.5 kPa).
Wolf recommends the use of a 
1
/
2
" (13) I.D.
commercial type flex hose; this is the minimum
size that may be used. All plumbing to the flex
hose must be 
3
/
4
" (19) minimum I.D. pipe. 
IMPORTANT NOTE: A separate external gas
shut-off valve must be located near the
rangetop in an accessible location. 
The Wolf gas rangetop functions up to
6,000' (1828 m) in altitude without any adjust-
ment. Installations above 6,000' (1828 m) need
the high altitude kit. Contact your Wolf dealer
for details. To obtain local dealer information,
visit the Locator section of our website,
wolfappliance.com.
You must follow all National Electrical Code
and gas regulations. In addition, be aware of
local codes and ordinances when installing your
services.
Refer to the installation instructions
shipped with each Wolf product for detailed
specifications.