Planning Information
60"
(1524)
Gas Ranges
M O D E L S   R 6 0 6 D G   /   R 6 0 6 F   /   R 6 0 6 C G   /   R 6 0 4 C F   /   R 6 0 4 G F
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications
for overall dimensions, finished rough opening
dimensions and installation specifics.
IMPORTANT NOTE: Caution must be used in
planning the proper installation of the Wolf gas
range to avoid any fires or damage to adjacent
cabinetry or kitchen equipment. Please follow
the minimum clearances established in the
finished rough opening dimensions as shown in
the Installation illustration.
IMPORTANT NOTE: A minimum 5" (127) riser is
required when installing a gas range against a
combustible surface. A minimum 10" (254) riser
is required when installing a gas range with a
charbroiler or griddle against a combustible
surface.
It is recommended that you use a Wolf Pro
wall or island ventilation hood or hood liner
with the Wolf gas range. Pro Ventilation infor-
mation can be found on our website, wolfappli-
ance.com. Also refer to the Wolf Design Guide
for Pro ventilation recommendations.
The Wolf gas range requires a 110 /120 V
AC, 60 Hz electrical supply to operate the
electronic ignition system. The 6' (1.8 m) power
supply cord provided with the range is
equipped with a 3-prong, grounded plug for
protection against shock hazard. The service
should have its own 15 amp circuit breaker.
Locate electrical and gas supply within the
shaded area shown in the Installation illustra-
tion.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
Wolf gas ranges are designed to operate on
natural gas at 5" (12.5 mb) WC (water column)
pressure or LP (propane) gas at 10" (25 mb)
WC pressure. The minimum line pressure for
natural gas is 7" (17.5 mb) WC and 11"
(27.4 mb) WC for LP gas. The maximum gas
supply pressure to the regulator should never
exceed 14" (34.9 mb) WC; .5 psi (3.5 kPa).
Wolf recommends the use of a 
1
/
2
" (13) I.D.
commercial type flex hose; this is the minimum
size that may be used. All plumbing to the flex
hose must be 
3
/
4
" (19) minimum I.D. pipe. 
IMPORTANT NOTE: A separate external gas
shut-off valve must be located near the range in
an accessible location. 
The Wolf gas range functions up to 6,000'
(1828 m) in altitude without any adjustment.
Installations above 6,000' (1828 m) need the
high altitude kit. Contact your Wolf dealer for
details. To obtain local dealer information,
visit the Locator section of our website,
wolfappliance.com.
You must follow all National Electrical Code
and gas regulations. In addition, be aware of
local codes and ordinances when installing your
services.
Refer to the installation instructions
shipped with each Wolf product for detailed
specifications.