3.2.2 ENGINE SPECIFICATIONS
Rated Horsepower @ 3600 RPM
30
Displacement
992cc
Spark Plug Type
Champion RC14YC or Equivalent
Spark Plug Gap
0.040 inch or (1.01 mm)
Gasoline Capacity
16 U.S. gallons
Oil Type
Summer – SAE 30, Winter – 
5W-30 Synthetic or 10W-30 
Oil Capacity
w/ Filter Change = 1.7 Qts., w/o 
Filter Change = 1.4 Qts.
Run Time/Fuel Consumption-1/2 
Load
10 Hours / 1.6 gallons per hour
3.3 GENERAL 
RECOMMENDATIONS
The warranty of the generator does not cover items that have been 
subjected to operator abuse or negligence. To receive full value from the 
warranty, the operator must maintain the generator as instructed in this 
manual.
Some adjustments will need to be made periodically to properly maintain 
the generator.
All adjustments in the Maintenance section of this manual should be made 
at least once each season. Follow the requirements in the "Maintenance 
Schedule" chart.
NOTE:
Once a year, replace the spark plug and replace the air filter. A new 
spark plug and clean air filter assure proper fuel-air mixture and help 
the engine run better and last longer.
3.3.1 GENERATOR MAINTENANCE
Generator maintenance consists of keeping the unit clean and dry. Operate 
and store the unit in a clean dry environment where it will not be exposed 
to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots 
in the generator must not become clogged with snow, leaves, or any other 
foreign material.
Check the cleanliness of the generator frequently and clean when dust, 
dirt, oil, moisture or other foreign substances are visible on its exterior 
surface.
  Never insert any object or tool through the air cooling 
slots, even if the engine is not running.
NOTE:
DO NOT use a garden hose to clean generator. Water can enter the 
engine fuel system and cause problems. In addition, if water enters 
the generator through cooling air slots, some water will be retained in 
voids and crevices of the rotor and stator winding insulation. Water and 
dirt buildup on the generator internal windings will eventually decrease 
the insulation resistance of these windings.
3.3.2  TO CLEAN THE GENERATOR
Use a damp cloth to wipe exterior surfaces clean.
• 
A soft, bristle brush may be used to loosen caked on dirt, oil, etc.
• 
A vacuum cleaner may be used to pick up loose dirt and debris.
• 
Low pressure air (not to exceed 25 psi) may be used to blow away 
• 
dirt. Inspect cooling air slots and openings on the generator. These 
openings must be kept clean and unobstructed.
3.3.3 ENGINE MAINTENANCE
DANGER
  When working on the generator, always disconnect 
negative cable from battery. Also disconnect spark 
plug wires from spark plugs and keep wire away from 
spark plugs.
3.3.4  CHECKING OIL LEVEL
See the “BEFORE STARTING THE GENERATOR” section for information on 
checking the oil level. The oil level should be checked before each use, or 
at least every eight hours of operation. Keep the oil level maintained.
  Hot oil may cause burns. Allow engine to cool before 
draining oil. Avoid prolonged or repeated skin 
exposure with used oil. Thoroughly wash exposed 
areas with soap.
3.3.5  CHANGING THE OIL AND OIL FILTER
Change the oil and filter after the first 30 hours of operation. Change the 
oil every 100 hours thereafter. If running this unit under dirty or dusty 
conditions, or in extremely hot weather, change the oil more often.
NOTE:
Whenever possible, run engine for approximately five (5) minutes to 
get the engine oil hot. This will aid in draining the oil.
Use the following instructions to change the oil while the engine is still 
warm:
Clean area around oil drain hose and plug.
• 
Remove oil drain plug from end of hose and oil fill plug to drain oil 
• 
completely into a suitable container.
When oil has completely drained, install oil drain plug and tighten 
• 
securely.
Place a suitable container beneath the oil filter and turn filter 
• 
counterclockwise to remove. Discard according to local regulations.
Coat gasket of new filter with clean engine oil. Turn filter clockwise until 
• 
gasket contacts lightly with filter adapter. Then tighten an additional 
3/4 turn.
Fill oil sump with recommended oil. (See “Before Starting the 
• 
Generator” for oil recommendations).
Wipe up any spilled oil.
• 