Removal and Replacement Procedures 
2-74 
HP ProLiant ML570 Generation 2 Server Maintenance and Service Guide 
Re-entering the Server Serial Number 
After replacing the system tray or clearing the NVRAM, the server serial number must be re-
entered. To re-enter the serial number: 
1.  During the server startup sequence, press the F9 key to access RBSU. 
2. Select 
the 
System Options menu. 
3. Select 
Serial Number. The following warning is displayed: 
WARNING! WARNING! WARNING! The serial number is loaded into the 
system during the manufacturing process and should NOT be 
modified. This option should ONLY be used by qualified service 
personnel. This value should always match the serial number 
sticker located on the chassis. 
Press the Enter key to clear the warning. 
4.  Enter the serial number and press the Enter key. 
5. Press 
the 
Escape key to close the menu. 
6. Press 
the 
Escape key to exit RBSU. 
7. Press 
the 
F10 key to confirm exiting RBSU. The server will automatically reboot.