Adtran MX2800 M13 Benutzerhandbuch

Seite von 200
9-22    
61200290L1-1G
Section 9, Transaction Language 1 (TL1)
MX2800 M13 Multiplexer User Manual
FMT
ENUM
One of the following:
• CBIT
• M13
Sets framing format to match the format of 
the receive signal at the network interface
• The framing format s set to CBIT
• The framing format is set to M13
LINELEN
ENUM
One of the following:
• LONG
• SHORT
Identifies Network DS3 line length
• LONG - exceeds 50 feet.
• SHORT - less than 50 feet.
RMTLPBK
ENUM
One of the following:
• DISABLE
• EITHER
• FEAC
• CBIT
Indicates whether the unit will respond to 
remote loopbacks over FEAC, CBIT, 
EITHER, or if remote loopbacks are disabled
• DISABLE - do not respond
• EITHER - respond over either FEAC or 
CBIT
• FEAC - respond over FEAC
• CBIT - respond over CBIT
SYSCARDARLY
Y/N
Y or [N]
Identifies status of System Controller Card A 
alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm
SYSCARDBRLY
Y/N
Y or [N]
Identifies status of System Controller Card B 
alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm
SYSCARDCOMMRLY
Y/N
Y or [N]
Identifies status of System Communication 
Fail alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm
SYSCARDRLY
Y/N
Y or [N]
Identifies status of System Controller Card 
alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm
TMG
ENUM
One of the following:
• LPD
• INT
Identifies timing supply for the DS3
• LPD - loop timed
• INT - internal timing source
Table 9-6.  TL1 Editing Data Dictionary for DS3 (Continued)
Keyword
Type
Domain
Description