2. SPECIFICATIONS
2-1. Unit Specifications
 Model Number
STB0810C1
STB1010C1
STB1020C1
STB1220C1
  Voltage (V)
115
115
230 / 208
230 / 208
 Performance
COOLING
Cooling Capacity
BTU/h
8,200
10,200
9,700 / 9,500 11,500 / 11,300
 Air Flow....Hi
CFM (CMM)
270 (7.65)
270 (7.65)
270 (7.65)
270 (7.65)
 Dihumidification
Pints/h
2.0
2.7
2.6
3.2
 Electrical Rating
 Available voltage range
V
104 ~ 126
253 ~ 187
 Cooling
Amperes
A
8.3
10.6
5.0 / 5.3
6.1 / 6.6
Watts
W
940
1,200
1,140  / 1,110
1,350  / 1,330
Power factor
%
98
98
99 / 100
96 / 97
EER
BTU/hW
8.7
8.5
8.5 / 8.5
8.5 / 8.5
 Starting amperes
A
43
53
30
34
 Recommeded Circuit Protection
A
15
15
15
15
 Plug Type
Parallel
Parallel
Tandem
Tandem
 Features
 Controls / Temperature control
Mechanical / Thermostat
 Control unit
 Timer
 Fan speeds
2
2
2
2
 Airflow direction (Indoor)
Horizontal
Manual
Vertical
Manual
 Air filter
Washable
 Air exhaust
 Yes
 Compressor
Rotary (Hermetic)
 R22-Amount charged at shipment
OZ
20.1
28.2
23.3
28.2
 Refrigerant control
Capillary tube
 Operation sound
   Indoor : Hi / Lo
dB-A
57 / 55
60 / 57
60  / 57
60 / 57
Outdoor : Hi / Lo
dB-A
63 / 60
68 / 64
68 / 64
68 / 64
 Dimensions & Weight
 Unit dimensions
Height
In
15-3/4
 (Refer to page 7)
Width
In
25-15/16
Depth
In
21-1/2
 Package dimensions Height
In
18-5/16
Width
In
29-1/8
Depth
In
24-11/16
 Weight
Net
lbs
82
90
89
93
Shipping
lbs
93
101
100
104
 Shipping volume
Cuft
7.62
DATA  SUBJECT  TO  CHANGE  WITHOUT  NOTICE.
Parallele
115V
15AMP
Tandem
230/208V
15AMP
Perpendicular
230/208V
20AMP
Wall Receptacles
Wall Sleeve Dimension
Remarks: Rating conditions are:
     Cooling :   Indoor air temperature      80°F D.B. /  67°F W.B.  Heating :   Indoor air temperature      70°F D.B.
                     Outdoor air temperature   95°F D.B. /  75°F W.B.                   Outdoor air temperature    47°F D.B. /  43°F W.B.
Models
STB0810C1
STB1010C1
STB1020C1
STB1220C1